The Liebert Hipulse-U offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. The Liebert Hipulse-U offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs.

 

Application

Information Technology

Large Internet Data centers

Coloration Facilities

Server Farms

Internet Service Providers

 

Telecommunication

Mobile (3G,4G)

Fixed (including WLL)

MSC, BSC centers

Industrial Automation

Process Control Equipment

Motion (digital drives and robotics)

Transport Automation

Airport automation

Railways and Road transport automation and ticket booking

 

Corporate Parks

Banking, Insurance and Financial Services.

Credit Card Operation

Stock Exchange Operation

Software Development Houses/Software Technology Parks

BPO/KPO/EPO Operation

 

Building Automation

Access Control

Security System

Fire Alarm System

Medical Diagnostics

Magneto Resonant Imaging

CT Scanning/Cath Lab

Multiple medical imaging units

 

Satellite

Uplinking

Earth Stations

Broadcasting & Entertainment

 

Features To Protect Your Network

Fully Digital, twin DSP controlled

Rated at 0.9 output power factor to deliver more active power

Handle leading power factor loads without KW derating under specified conditions

On-Line Double Conversion IGBT-based PWM Inverter

Wide input voltage tolerance(+20/-20%)

Wide input frequency range of 45Hz to 65Hz

High overload capability of static

bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds)

Capability to handle:

High crest factor loads

100% non-linear loads

100% unbalanced loads

Built-in maintenance bypass

Front access for spares replacement and preventive maintenance

Easy Dual bus configuration architecture

Adjustable frequency

synchronization window up to 6% in the static bypass

Field protocols ModBus / Jbus

Network protocols SNMP

Overload capability of the UPS:

110% Ful load for 60 minutes

125% full load for 10 minutes

150% full load for 1 minutes

Compact footprint

 

Built Investment Protection

Automatic battery testing

Field settability of EOD of the battery

Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour)

Protection against deep discharge of battery

Short-circuit proof inverter

Back-feed protection

D-level lightning protection

With 3 auxiliary power supply to ensure redundancy under any condition

Standard dry contacts

Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range

Choice of array of input harmonic filter options

Temperature-compensated battery charging (optional)